(h) Figure 1. The following figure
two compartment septic tank.illustrates a
Ground Surface.
Depth May Vary, But Not
Exceed 18 inches unless a riser
is installed on each cleanout and
the tank manufacturer allows it.
Clean Out--.Sand Cushion
Not to Scale
(i) Figure 2. The following figure illustrates two
septic .tanks in series.
GROUND SURFACE) -~iwa-Ewe
The first tank must be about
one-half to two-thirds of the
total volume of both tanks.Liquid surface is
same level in
both tanks. CleanDepth May Vary, But Not
Exceed 18 inches unless a riser
is installed on each cleanout and
the tank manufacturer allows it.
OutSOutflow
Outflow pipe is
at least /2" lower
than first tank's
inflow pipe.-- Sand Cushion
12 rflraq 3 am1ry A I7 Team R e 4
Not to Scale
Upcoming Pages
Here’s what’s next.
Search Inside
This issue can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Periodical.
Texas. Secretary of State. Texas Register, Volume 12, Number 1, Pages 1-51, January 2, 1987, periodical, January 2, 1987; Austin, Texas. (https://texashistory.unt.edu/ark:/67531/metapth243845/m1/24/: accessed April 19, 2024), University of North Texas Libraries, The Portal to Texas History, https://texashistory.unt.edu; crediting UNT Libraries Government Documents Department.