MASH test 3-11 on the 5-inch cast in place deck barrier anchors

One of 25 reports in the series: Research report (Austin, Tex.) available on this site.

PDF Version Also Available for Download.

Description

"A full-scale crash test was performed to evaluate the impact performance of a Texas T223 concrete beam and post bridge rail anchored to a 5-nch cast-in-place deck (CIPD). The testing followed the MASH standards for Test Level 3 ( TL-#) longitudinal barriers. The test performed was American Association of State Highways and Transportation Officials (AAHSTO) Manual for Assessing Safety Hardware (MASH) test 3-11, which involves a 2270P (500 lb) pickup truck impacting the critical impact point (CIP) of the barrier at a nominal impact speed and angle of 62 mi/h and 25degress, respectively. This test evaluated the strength of the ... continued below

Physical Description

x, 69 p. : ill. (chiefly col.) ; 28 cm.

Creation Information

Bligh, Roger P.; Menges, Wanda L. & Arrington, Dusty R. October 2011.

Context

This report is part of the collection entitled: Texas State Publications and was provided by UNT Libraries Government Documents Department to The Portal to Texas History, a digital repository hosted by the UNT Libraries. It has been viewed 103 times , with 9 in the last month . More information about this report can be viewed below.

Who

People and organizations associated with either the creation of this report or its content.

Publisher

  • Texas Transportation Institute
    Publisher Info: Texas Transportation Institute, Texas A & M University System
    Place of Publication: College Station, Texas

Provided By

UNT Libraries Government Documents Department

Serving as both a federal and a state depository library, the UNT Libraries Government Documents Department maintains millions of items in a variety of formats. The department is a member of the FDLP Content Partnerships Program and an Affiliated Archive of the National Archives.

Contact Us

What

Descriptive information to help identify this report. Follow the links below to find similar items on the Portal.

Titles

  • Main Title: MASH test 3-11 on the 5-inch cast in place deck barrier anchors
  • Added Title: Roadside safety device crash testing program
  • Series Title: Research report (Austin, Tex.)

Description

"A full-scale crash test was performed to evaluate the impact performance of a Texas T223 concrete beam and post bridge rail anchored to a 5-nch cast-in-place deck (CIPD). The testing followed the MASH standards for Test Level 3 ( TL-#) longitudinal barriers. The test performed was American Association of State Highways and Transportation Officials (AAHSTO) Manual for Assessing Safety Hardware (MASH) test 3-11, which involves a 2270P (500 lb) pickup truck impacting the critical impact point (CIP) of the barrier at a nominal impact speed and angle of 62 mi/h and 25degress, respectively. This test evaluated the strength of the barrier and its anchorage to the 5-inch CIPD."

Physical Description

x, 69 p. : ill. (chiefly col.) ; 28 cm.

Notes

"October 2011. Published: December 2011."

Includes bibliographical references.

Subjects

Language

Item Type

Identifier

Unique identifying numbers for this report in the Portal or other systems.

Collections

This report is part of the following collection of related materials.

Texas State Publications

This growing collection of materials produced by the State of Texas includes agency annual reports, legislative publications, statistical reports, and various state government reports and periodicals.

What responsibilities do I have when using this report?

When

Dates and time periods associated with this report.

Creation Date

  • October 2011

Covered Time Period

Added to The The Portal to Texas History

  • Aug. 12, 2013, 11:05 p.m.

Usage Statistics

When was this report last used?

Yesterday: 0
Past 30 days: 9
Total Uses: 103

Where

Geographical information about where this report originated or about its content.

Publication Place

Map Information

  • map marker Automatically generated Place Name coordinates.
  • map marker Automatically generated Publication Place coordinates.
  • Repositioning map may be required for optimal printing.

Mapped Locations

Interact With This Report

Here are some suggestions for what to do next.

Start Reading

PDF Version Also Available for Download.

International Image Interoperability Framework

IIF Logo

We support the IIIF Presentation API

Bligh, Roger P.; Menges, Wanda L. & Arrington, Dusty R. MASH test 3-11 on the 5-inch cast in place deck barrier anchors, report, October 2011; College Station, Texas. (texashistory.unt.edu/ark:/67531/metapth326631/: accessed August 19, 2018), University of North Texas Libraries, The Portal to Texas History, texashistory.unt.edu; crediting UNT Libraries Government Documents Department.