59 Matching Results

Search Results

Prairie Oil and Gas Company Office Building, Eastland, Texas: Second Floor Framing Plan

Description: Second floor framing plan for an office building commissioned by the Prairie Oil and Gas Company in Eastland, Texas. It features framing lines, column placement, wall edge lines, and measurements. Other sections include a beam schedule, section thru basement, beam schedule basement, framing plan of floor over basement, and typical detail of interior columns and beams.
Date: October 13, 1919
Creator: Castle, David S.
Partner: Tittle-Luther/Parkhill, Smith and Cooper, Inc.

Prairie Oil and Gas Company Office Building, Eastland, Texas: Elevation, Door, & Railing Details

Description: Elevation, door, and railing details for an office building commissioned by the Prairie Oil and Gas Company in Eastland, Texas. Sections include a cross section, first floor detail of corridor openings, door "A" basement, door "B" basement, door "C" 1st & 2nd floors, toilet door "E" 1st & 2nd floors, gate "G" 1st floor, main entrance door "A", door "C" basement, door "F" 1st floor, and multiple wooden railing components.
Date: October 13, 1919
Creator: Castle, David S.
Partner: Tittle-Luther/Parkhill, Smith and Cooper, Inc.

Prairie Oil and Gas Company Office Building, Eastland, Texas: Elevation, Door, & Railing Details

Description: Elevation, door, and railing details for an office building commissioned by the Prairie Oil and Gas Company in Eastland, Texas. Sections include a cross section, first floor detail of corridor openings, door "A" basement, door "B" basement, door "C" 1st & 2nd floors, toilet door "E" 1st & 2nd floors, gate "G" 1st floor, main entrance door "A", door "C" basement, door "F" 1st floor, and multiple wooden railing components.
Date: October 13, 1919
Creator: Castle, David S.
Partner: Tittle-Luther/Parkhill, Smith and Cooper, Inc.

Auto Sales Building, Abilene, Texas: Roof Plan

Description: Roof plan for an auto sales building commissioned by George L. Minter Sr. in Abilene, Texas. It includes measurements, beam placement lines, labels, and notes. Other sections include typical detail of roof & ceiling framing, detail of pipe column connection at tie beam, detail of stirrups, beam notes, tie beam schedule, and skylight detail.
Date: March 13, 1946
Creator: David S. Castle Co.
Partner: Tittle-Luther/Parkhill, Smith and Cooper, Inc.

Prairie Oil and Gas Company Office Building, Eastland, Texas: Elevation & Window Detail

Description: Elevation rendering and window details for an office building commissioned by the Prairie Oil and Gas Company in Eastland, Texas. Sections include end elevation, alley elevation, 3" scale detail of second story d.h. windows, and 3" scale detail of first story d.h. windows with transom. The end and alley elevation renderings have windows, wall edge lines, measurements, labels, and base boundary lines. The window details have parts including head, meeting rail, transom bar, mullion, and sill.
Date: October 13, 1919
Creator: Castle, David S.
Partner: Tittle-Luther/Parkhill, Smith and Cooper, Inc.

Prairie Oil and Gas Company Office Building, Eastland, Texas: Front Elevation

Description: Elevation renderings for an office building commissioned by the Prairie Oil and Gas Company in Eastland, Texas. It includes front elevation and a section thru & elevation of main entrance. They have windows, doors, measurements, wall texture lines, roof trim, and labels.
Date: October 13, 1919
Creator: Castle, David S.
Partner: Tittle-Luther/Parkhill, Smith and Cooper, Inc.

Prairie Oil and Gas Company Office Building, Eastland, Texas: Basement & Foundation Plan

Description: Basement and foundation plan for an office building commissioned by the Prairie Oil and Gas Company in Eastland, Texas. It includes column placement, wall boundary lines, notes, and rear elevation boiler connections for side elevation.
Date: November 13, 1919
Creator: Castle, David S.
Partner: Tittle-Luther/Parkhill, Smith and Cooper, Inc.

Prairie Oil and Gas Company Office Building, Eastland, Texas: Second Floor Mechanical Plans

Description: Second floor mechanical plan for an office building commissioned by the Prairie Oil and Gas Company in Eastland, Texas. It includes brown colored walls, column placement, door orientation lines, fan placement, measurements, and labels.
Date: October 13, 1919
Creator: Castle, David S.
Partner: Tittle-Luther/Parkhill, Smith and Cooper, Inc.

Prairie Oil and Gas Company Office Building, Eastland, Texas: First Floor Mechanical Plans

Description: First floor mechanical plan for an office building commissioned by the Prairie Oil and Gas Company in Eastland, Texas. It includes brown colored walls, window placement, fan placement, door orientation lines, measurements, and labels.
Date: October 13, 1919
Creator: Castle, David S.
Partner: Tittle-Luther/Parkhill, Smith and Cooper, Inc.

Prairie Oil and Gas Company Office Building, Eastland, Texas: Wood Floor Construction

Description: Wood floor construction plan for an office building commissioned by the Prairie Oil and Gas Company in Eastland, Texas. It includes wood framing lines, column placement, wall edge lines, and measurements. Other sections include detail for column number 23 under second floor, and column footing.
Date: October 13, 1919
Creator: Castle, David S.
Partner: Tittle-Luther/Parkhill, Smith and Cooper, Inc.

Big Lake High School Gymnasium: Electrical Plan

Description: Mechanical plan for a high school gymnasium in the Reagan County Independent School District. It includes a drawing of the electrical floor plan of the building which shows the electrical lines and connections throughout the building. Also included is an auditorium panel schedule and a lighting fixture schedule.
Date: November 13, 1954
Creator: David S. Castle Co.
Partner: Tittle-Luther/Parkhill, Smith and Cooper, Inc.

Big Lake High School Auditorium: Heating and Air Conditioning Plans

Description: Mechanical plan for a high school auditorium in the Reagan County Independent School District. It includes a set of drawings that detail various aspects of the heating, air conditioning, and ventilation systems; most drawings show piping details, and one shows a cross section of the auditorium.
Date: November 13, 1954
Creator: David S. Castle Co.
Partner: Tittle-Luther/Parkhill, Smith and Cooper, Inc.

Big Lake High School Auditorium: Heating and Ventilation Systems

Description: Mechanical plan for a high school auditorium in the Reagan County Independent School District. It includes a drawing of the building's floor plan with labels concerning the various locations within the building; also labeled are notations for the planned electrical system and an equipment schedule detailing more specifics about the electrical system.
Date: November 13, 1954
Creator: David S. Castle Co.
Partner: Tittle-Luther/Parkhill, Smith and Cooper, Inc.

Big Lake High School Auditorium: Plumbing Plan

Description: Mechanical plan for a high school auditorium in the Reagan County Independent School District. It includes a drawing of the building's floor plan with details that highlight the planned plumbing system. Also included is a diagram that details the plumbing riser diagram for both the men's and women's toilets.
Date: November 13, 1954
Creator: David S. Castle Co.
Partner: Tittle-Luther/Parkhill, Smith and Cooper, Inc.

Big Lake High School Auditorium: Electrical Plan

Description: Mechanical plan for a high school auditorium in the Reagan County Independent School District. It includes a floor plan for the building with notations concerning the electrical work drawn within; the electrical details show the lines, and connections in each part of the building. Also included is a diagram of the sound system and a smaller drawing showing the covered passage electrical plan.
Date: November 13, 1954
Creator: David S. Castle Co.
Partner: Tittle-Luther/Parkhill, Smith and Cooper, Inc.