TABLE 2.5.2.8-1
CANDIDATE FIBROUS INSULATIONS
Material Min-K Min-K Min-K MicrotherLa Cotronics
Properties TE-1400 TE-1800 2000 20 CR 360 HS CBCF-3 CBCF-4
Thermal Conductivity 2Btu-ft . 0090 . 0081 . 0099 . 0072 . 0220 . 0578 . 0110
ft -hr-*F
392*F (< 10-4 torr)
842'F ( < 10-4 torr) .0118 .0116 . 0144 .0144 .0300 . 0664 .0176
1202*F ( < 10-4 torr) . 0153 .0156 . 0217 . 0240 .0410 .0751 .0254
1652*F (< 10~4 torr) (15600F)* .0202* .0202 . 0355* .0445 .0774 .0896* .0364*
Density lbs/cubic ft 20 20 20 20 20 14
Continuous Service Temperature (*F) 1400 1800 2000 1832 2300
Compressive Strength (psi)
5% Compression 75 Non Load 80 50
Non
8% Compression 145 Bearing 170 Load
Bearing
Limit 150 350 150
Average Transverse Strength (psi) 65 50 55
Modulus of Rupture (psi) 80 68 16-20 55
Modulus of Elasticity (psi) 2300 1150
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Kilowatt Isotope Power System, Phase II Plan. Volume IV. Teledyne FSCD vs GDS, report, March 15, 1978; Timonium, Maryland. (https://texashistory.unt.edu/ark:/67531/metadc1055866/m1/116/: accessed July 16, 2024), University of North Texas Libraries, The Portal to Texas History, https://texashistory.unt.edu; crediting UNT Libraries Government Documents Department.