Using (14) and (15) we have for VR
VR = 2. 02946 x 104 x 1. 128259 x 10-4 po = 124, 127 lb/in.
The maximum longitudinal stress on the cylinder is given by
1. 932 V __o a2
oL 2 + 2n (R) t
t
where
X = 1.3269 t = .170 R = 5.52 in.
then,
6L = 6467 psi
The yield point for 6061-T6 aluminum alloy at 220*F is 32.4 x 103 psi. Then the
margin of safety is
M. S. = 32400 - 1 = 4. 01
The maximum hoop stress in the cylinder is given by
2 V
6h = t R XR = 10696 psi
The margin of safety is:
S 32400 -1 = 2. 03
M.. - 10696-
For the stress on the end over we have: at r = b
(2
2 = 9. 7828 x 10-5 p0
drb
2
o- = E - hb = 9. 8 x 10 6 x 9. 7828 x 10-5 x 54. 21 x .484 =25154 psi
r = b76
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Matching Search Results
View 210 places within this report that match your search.Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Kilowatt Isotope Power System, Phase II Plan. Volume IV. Teledyne FSCD vs GDS, report, March 15, 1978; Timonium, Maryland. (https://texashistory.unt.edu/ark:/67531/metadc1055866/m1/90/?q=%22~1%22~1&rotate=270: accessed July 16, 2024), University of North Texas Libraries, The Portal to Texas History, https://texashistory.unt.edu; crediting UNT Libraries Government Documents Department.