Corrosion Resistance Recommendations from Long-Term
Exposure Testing of Post-Tensioning Systems
A.L. Kilduff
K.L. Moyer
G.E. McCool
M.E. Ahern
J.E. BreenCTR Technical Report:
Report Date:
Project:
Project Title:
Sponsoring Agency:
Performing Agency:0-4562-5F
May 2013
0-4562
Corrosion Resistance of Grouted Post-Tensioning Systems
Texas Department of Transportation
Center for Transportation Research at The University of Texas at AustinProject performed in cooperation with the Texas Department of Transportation and the Federal Highway
Administration.
Upcoming Pages
Here’s what’s next.
Search Inside
This report can be searched. Note: Results may vary based on the legibility of text within the document.
Tools / Downloads
Get a copy of this page or view the extracted text.
Citing and Sharing
Basic information for referencing this web page. We also provide extended guidance on usage rights, references, copying or embedding.
Reference the current page of this Report.
Kilduff, A. L.; Moyer, K. L.; McCool, G. E.; Ahern, M. E. & Breen, J. E. Corrosion Resistance Recommendations from Long-Term Exposure Testing of Post-Tensioning Systems, report, November 2013; Austin, Texas. (https://texashistory.unt.edu/ark:/67531/metapth639838/m1/5/: accessed May 6, 2024), University of North Texas Libraries, The Portal to Texas History, https://texashistory.unt.edu; crediting UNT Libraries Government Documents Department.